Core Cavity Weep™
CCV5020
What Core Cavity Weep does:
- It forms the bottom side of the bed joint of mortar at the exterior and interior shell of a CMU or Jumbo Brick
- It weeps both the core and cavity when CMU or Jumbo Brick is used as a veneer
- It’s easy to install (12" wide — 25' long rolls)
How to install Core Cavity Weep*
- Clean installation surface.
- Core/Cavity Weep should be positioned on flashings and waterstops with material centered on wall. Allow intermittent legs to extend into the wall cavity and to the exterior as illustrated.
- Apply bed joint of mortar.
- Install masonry units on bed of mortar, following normal installation procedures.
- Lightly score legs at face of wall, crack off by pushing downward while mortar is still plastic.
- Tool and finish mortar joints.
- Caution: CMU or Jumbo Brick Veneers must have cells no less than 3" wide.
Ordering and Shipping Information
| Roll Length (Feet) | 25
|
| Rolls per Box | 8
|
| Linear Feet per Box | 200
|
| Boxes per Pallet | 16
|
| Linear Feet per Pallet | 3200 |
Contact MTI at 1-800-879-3348 for specific cost to your destination.
Core Cavity Weep Specifications
2.5" (64 mm) wide weep legs offset on each side of continuous belt, at 9.5" (241 mm) on center; continuous belt 2" (51 mm) wide; and total width 1'-0" (305 mm).
Product Cutsheet: Download Product Cut Sheet
Popular
HyperSpecs® Wall Details featuring Core Cavity Weep
Browse Wall Details |
Browse Wall Details with Core Cavity Weep
*The installation listed provides the most common installation instructions. For specific installation details please find your wall detail in our